Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Int J Urol ; 26(2): 260-265, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30467901

RESUMO

OBJECTIVE: To evaluate the role of urine aquaporin 1 and perilipin 2 as biomarkers adjunct to renal mass biopsy in guiding the management of patients with small renal masses. METHODS: Preoperative aquaporin 1 and perilipin 2 levels in 57 patients with small renal masses undergoing partial nephrectomy were analyzed and compared with postoperative tumor histology. An algorithm was created utilizing aquaporin 1 and perilipin 2 in conjunction with renal mass biopsy. Cut-off values were implemented to maximize biomarker sensitivity and specificity. Renal mass biopsy utilization and intervention were then compared with rates in traditional renal mass biopsy algorithms. RESULTS: All clear cell and papillary renal cell carcinomas were correctly identified and assigned to the treatment path. All benign lesions were correctly sorted to a confirmatory renal mass biopsy path. Two chromophobe masses did not have elevated aquaporin 1 and perilipin 2, and would require renal mass biopsy. Compared with protocols that call for all small renal masses to be biopsied, confirmatory renal mass biopsy could have been safely avoided in 74% of patients with elevated aquaporin 1 and perilipin 2. Compared with protocols that do not utilize renal mass biopsy, surgical intervention would have been avoided in 23% of patients with benign masses. CONCLUSIONS: Aquaporin 1 and perilipin 2 possess high sensitivity and specificity for detecting clear cell and papillary renal cell carcinoma. Use of these markers might compliment renal mass biopsy in the characterization of small renal masses.


Assuntos
Aquaporina 1/urina , Biomarcadores Tumorais/urina , Carcinoma de Células Renais/cirurgia , Neoplasias Renais/cirurgia , Perilipina-2/urina , Idoso , Biópsia , Carcinoma de Células Renais/diagnóstico por imagem , Carcinoma de Células Renais/patologia , Carcinoma de Células Renais/urina , Feminino , Humanos , Rim/diagnóstico por imagem , Rim/patologia , Rim/cirurgia , Neoplasias Renais/diagnóstico por imagem , Neoplasias Renais/patologia , Neoplasias Renais/urina , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Nefrectomia/métodos , Seleção de Pacientes , Valor Preditivo dos Testes , Período Pré-Operatório , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Carga Tumoral
2.
J Endourol ; 31(2): 119-128, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-27897036

RESUMO

INTRODUCTION: Approximately 5% of angiomyolipomas (AMLs) are classified as "fat poor" due to lack of visually detectable fat on imaging, making them difficult to distinguish from renal cell carcinoma. Recent investigations have proposed CT and MR imaging features suggestive of fat-poor AML (fp-AML). Herein, we determined the frequency of these features in a cohort of fp-AMLs by retrospective review of preoperative imaging. METHODS: A pathology database query from January 2005 to August 2013 identified 49 renal specimens of AML with available imaging. A retrospective review of all CT and MR images of these 49 cases was conducted. Cases with visually detectable fat on imaging were excluded. RESULTS: A total of 26 fp-AMLs were identified. Thirteen lesions had available unenhanced CT images, of which eight (62%) were hyperdense compared to the adjacent renal parenchyma, while five (38%) were isodense. Twenty lesions had enhanced CT images: 14 (70%) and 6 (30%) with homogeneous and heterogeneous enhancement, respectively. Of the nine lesions with enhanced MR sequences, five (56%) were homogeneously enhancing, and four (44%) were heterogeneously enhancing. Eight of nine (89%) lesions had hypointense signal intensity (SI) on T2-weighted MR sequences, while one (11%) had hyperintense SI. None of the eight lesions displayed a decrease in signal on fat-suppressed sequences. CONCLUSIONS: In this study, we confirmed common imaging features of fp-AML: high attenuation on unenhanced CT sequences, homogeneous enhancement on CT, and hypointensity on T2-weighted MR. When these features are present, a renal mass biopsy may be prudent.


Assuntos
Angiomiolipoma/diagnóstico por imagem , Neoplasias Renais/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Angiomiolipoma/patologia , Carcinoma de Células Renais/diagnóstico , Diagnóstico Diferencial , Feminino , Humanos , Neoplasias Renais/patologia , Espectroscopia de Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
3.
J Endourol ; 28(12): 1429-34, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25238210

RESUMO

OBJECTIVE: To determine if patients with pathological, medical renal disease, defined as evidence of pathological abnormalities indicative of renal damage in the non-neoplastic partial nephrectomy specimens, have worsened functional outcomes following robot-assisted partial nephrectomy (RPN). MATERIALS AND METHODS: Sixty patients with and 101 without pathologically proven renal disease on non-neoplastic renal specimens were evaluated for differences in postoperative outcomes following RPN. Multiple linear regression modeling assessed for factors influencing early and late declines in renal function. RESULTS: The two groups were similar in all preoperative parameters. Both patients with and without pathological renal disease had similar lengths of hospitalization, transfusions, and complication rates. The percent change in the glomerular filtration rate was similar for patients with and without pathological renal disease (-8.8% vs -12.2%, p=0.194). Patients with pathological renal disease had less chronic kidney disease (CKD) upstaging than patients without renal disease (18.3% vs 39.6%, p=0.006). Increasing age (p=0.030) and higher preoperative glomerular filtration rates (p=0.044) predicted worse late percentage declines in renal function, while increased warm ischemia time predicted late CKD upstaging (p=0.043). CONCLUSION: The presence of pathological renal disease in non-neoplastic renal tissue did not place patients at risk for worsened postoperative complications or renal function deterioration following RPN.


Assuntos
Carcinoma de Células Renais/cirurgia , Taxa de Filtração Glomerular , Neoplasias Renais/cirurgia , Rim/cirurgia , Nefrectomia , Complicações Pós-Operatórias/fisiopatologia , Insuficiência Renal Crônica/fisiopatologia , Procedimentos Cirúrgicos Robóticos , Idoso , Creatinina/sangue , Progressão da Doença , Feminino , Humanos , Rim/patologia , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Complicações Pós-Operatórias/sangue , Complicações Pós-Operatórias/patologia , Período Pós-Operatório , Insuficiência Renal Crônica/sangue , Insuficiência Renal Crônica/patologia , Isquemia Quente/efeitos adversos
4.
J Endourol ; 28(5): 554-9, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24369853

RESUMO

PURPOSE: To evaluate the effects of a reverse thermosensitive polymer during ureteroscopy with laser lithotripsy in an in vivo porcine model. MATERIALS AND METHODS: Six pigs underwent general anesthesia followed by bilateral ureteroscopy with laser lithotripsy of stone phantoms while measuring intrapelvic renal pressures through bilateral nephrostomy tubes. The procedures were performed in one ureter with the reverse thermosensitive polymer and in the contralateral, control ureter without the reverse thermosensitive polymer. Stone migration lengths, operative times, laser times, laser energy usage, intrapelvic pressures, and postnecropsy histologic examinations of the ureters were compared between the two groups. RESULTS: Bilateral ureteroscopy with lithotripsy was successfully performed in five of six pigs. In one pig, only the unilateral control was performed, because the ureter was too narrow to complete the contralateral side. The mean laser time was 12.8 minutes shorter with the use of the reverse thermosensitive polymer group than in the controls (P=0.021). The procedure time, laser energy usage, and retropulsion length was shorter in the reverse thermosensitive polymer group, but did not reach significance. Between the two groups, there was no difference in mean renal pelvic pressures, peak renal pelvic pressures, or postprocedure histologic examinations of the ureters. CONCLUSIONS: The use of a reverse thermosensitive polymer during ureteroscopy with lithotripsy may have greater advantages beyond preventing stone retropulsion. Here, the use of a reverse thermosensitive polymer during ureteroscopy with lithotripsy resulted in a significant decrease in laser times. Further clinical investigations could further delineate the advantages of using a reverse thermosensitive polymer during intracorporeal lithotripsy.


Assuntos
Litotripsia a Laser/métodos , Polímeros/uso terapêutico , Cálculos Ureterais/terapia , Ureteroscopia/métodos , Animais , Feminino , Pelve Renal , Litotripsia a Laser/instrumentação , Modelos Animais , Nefrostomia Percutânea/instrumentação , Duração da Cirurgia , Polímeros/química , Suínos , Temperatura , Ureter/patologia
6.
Patient Saf Surg ; 7(1): 19, 2013 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-23731776

RESUMO

Robotic surgeries of long duration are associated with both increased risks to patients as well as distinct challenges for care providers. We propose a surgical checklist, to be completed during a second "time-out", aimed at reducing peri-operative complications and addressing obstacles presented by lengthy robotic surgeries. A review of the literature was performed to identify the most common complications of robotic surgeries with extended operative times. A surgical checklist was developed with the goal of addressing these issues and maximizing patient safety. Extended operative times during robotic surgery increase patient risk for position-related complications and other adverse events. These cases also raise concerns for surgical, anesthesia, and nursing staff which are less common in shorter, non-robotic operations. Key elements of the checklist were designed to coordinate operative staff in verifying patient safety while addressing the unique concerns within each specialty. As robotic surgery is increasingly utilized, operations with long surgical times may become more common due to increased case complexity and surgeons overcoming the learning curve. A standardized surgical checklist, conducted three to four hours after the start of surgery, may enhance perioperative patient safety and quality of care.

7.
Case Rep Med ; 2013: 730549, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23710191

RESUMO

We present a case of persistent pneumaturia of one-year duration in a fifty-five-year-old male with a history of spinal cord injury. The evaluation demonstrated gas throughout the collecting system attributable to a urinary tract infection with a gas-forming organism, Klebsiella pneumoniae.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...